Service fresh water cooling system (TM 55-1925-205-23).
Tag and disconnect wires from oil pressure switch

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  839    840    841    842    843  844  845    846    847    848    849  
img
. . . . . . .
TM 55-2815-574-24
0172
FIELD MAINTENANCE
ENGINE 
AUTO SHUTDOWN SYSTEM LOW OIL PRESSURE SWITCH REPLACEMENT
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General mechanic's tool kit
Engineer 88L
(WP 0179, Table 1, Item 130)
Drain pan (WP 0179, Table 1, Item 87)
References
FM 4-01.502
TM 55-1925-205-10
Materials/Parts
Antiseizing tape (WP 0178, Table 1, Item 37)
Hazardous material spill clean-up kit
Equipment Condition
(WP 0178, Table 1, Item 34)
Propulsion module ventilated
Marker tags, with metal eyelet patch Qty: 2
(TM 55-1925-205-23)
(WP 0178, Table 1, Item 36)
REMOVAL
WARNING
Remove all jewelry before conducting maintenance. Do not wear watches, rings,
identification tags, or other jewelry which could short across electrical components or catch
on vehicle components. Failure to comply may result in personnel injury or death.
NOTE
Tag all wires prior to disconnection for identification when installing the new switch.
1.
Place A3 breaker switch (Figure 1, Item 1), located on A10 panel, in OFF position. Refer to
TM 55 1925-205-10 for breaker location.
WARNING
Before attempting any maintenance, ensure power supply (switches, circuit breakers, etc.)
has been disconnected and locked/tagged out against unauthorized accidental start-up or
else death or serious injury due to electric shock and/or moving machinery could occur.
2.
Lock Out/Tag Out (LO/TO) A3 breaker switch (Figure 1, Item 1). Refer to FM 4-01.502 for LO/TO procedure.
Figure 1. A3 Breaker Switch.