TM 55-2815-574-24
FIELD MAINTENANCE
ENGINE
ELECTRICAL SYSTEM NORMAL STOP PUSHBUTTON MOUNTING BRACKET REPLACEMENT
INITIAL SETUP:
Tools and Special Tools
References
General mechanic's tool kit
TM 55-1925-205-10
Equipment Condition
Materials/Parts
Electrical system normal stop pushbutton
Lockwasher Qty: 2 (WP 0180, Table 1, Item 106)
Personnel Required
Engineer 88L
REMOVAL
1.
Remove two capscrews (Figure 1, Item 2) and lockwashers (Figure 1, Item 1) securing bracket
(Figure 1, Item 4) to thermostat housing (Figure 1, Item 5).
2.
Remove bracket (Figure 1, Item 4) from thermostat housing (Figure 1, Item 5) and discard.
END OF TASK
INSTALLATION
1.
Install new mounting bracket (Figure 1, Item 4) on thermostat housing (Figure 1, Item 5).
2.
Install capscrews (Figure 1, Item 2) and lockwashers (Figure 1, Item 1) on mounting bracket
(Figure 1, Item 4).
3.
Tighten capscrews (Figure 1, Item 2).
4.
Install new (adhesive-backed) legend plate (Figure 1, Item 3) on mounting bracket (Figure 1, Item 4).
0160-1