TM 55-2815-574-24
0115
FILLING LUBE OIL SYSTEM CRANKCASE - Continued
10.
Monitor level of oil in clean oil storage drum and sump dipstick (Figure 3, Item 1).
Figure 3. Dipstick.
11.
Continue filling until manufacturer's recommended level for equipment is reached
(32 qt (30 L) of oil with filter changed). Do not overfill.
12.
Stop pump.
WARNING
Do not allow any oil/fuel to drip onto deck. Failure to comply may result in
personnel injury.
Accidental or intentional introduction of liquid contaminants into the environment
may result in a violation of state, federal, and military regulations. Refer to local
environmental office for information concerning storage, use, and disposal of
these liquids. Failure to comply may cause damage to environment and health
of personnel. Seek medical attention in the event of injury.
13.
Disconnect pump discharge hose from forward coupling half (Figure 2, Item 2) and wipe clean with spill
clean-up kit.
14.
Reconnect combination hose coupling and pipe nipple to end of pump discharge hose.
15.
Place end of pump discharge hose inside dirty oil storage drum.
16.
Remove end of pump suction hose from clean oil storage drum.
NOTE
To stop pump in an emergency, depress the emergency stop button. The emergency stop
button must be reset to restart the pump. To reset, pull emergency stop button out.
17.
Turn on pump. A green signal light will indicate pump is running and will turn off when all oil has been
removed from pump.
18.
Disconnect combination hose coupling and pipe nipples from ends of pump discharge hose and pump
suction hose and wipe components clean with spill clean-up kit.
0115-5