FILLING LUBE OIL SYSTEM CRANKCASE - Continued
19.
Replace dust cap (Figure 2, Item 1) on forward coupling half (Figure 2, Item 2).
20.
Remove LO/TO from A3 breaker switch. Refer to FM 4-01.502 for LO/TO procedure.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Disconnect pump electrical cord from 115 VAC shore outlet.
2.
Store pump electrical cord and pump suction and discharge hoses on FLOCS cart.
3.
Stow FLOCS cart in BII container (TM 55-1925-205-10).
4.
Clean up spilled fluid with a spill clean-up kit and dispose of spill clean-up kit waste in accordance with
local procedures.
5.
Install operator`s cab side access panel (TM 55-1925-205-10).
6.
Install intake plenum side access panel (TM 55-1925-205-10).
7.
Perform operational check of diesel engine (TM 55-1925-205-10).
END OF TASK
END OF WORK PACKAGE