TM 55-2815-574-24
0161
REMOVAL - Continued
3.
Tag and disconnect two wires (Figure 2, Item 1) from hour meter (Figure 2, Item 3).
4.
Push hour meter (Figure 2, Item 3) out of mounting bracket (Figure 2, Item 2).
END OF TASK
INSTALLATION
1.
Position new hour meter (Figure 2, Item 3) on bracket (Figure 2, Item 2).
2.
Using both thumbs on steel rim of hour meter (Figure 2, Item 3), press hour meter into mounting bracket
(Figure 2, Item 2).
3.
Connect two wires (Figure 2, Item 1) on hour meter (Figure 2, Item 3).
4.
Remove tags from wires (Figure 2, Item 1).
5.
Remove LO/TO from A3 breaker switch. Refer to FM 4-01.502 for LO/TO procedure.
Figure 2. Hour Meter Bracket.
END OF TASK
FOLLOW-ON MAINTENANCE
Perform operational check of diesel engine (TM 55-1925-205-10).
END OF TASK
END OF WORK PACKAGE