RAW WATER PUMP ZINC ANODE PLUG REPLACEMENT

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  773    774    775    776    777  778  779    780    781    782    783  
img
TM 55-2815-574-24
0153
INSTALLATION
1.
Install new zinc anodes (Figure 3, Item 2) into support plugs (Figure 3, Item 1).
2.
Wrap support plug (Figure 3, Item 1) threads with antiseizing tape.
3.
Install support plugs (Figure 3, Item 1) with zinc anodes (Figure 3, Item 2) into heat exchanger
(Figure 3, Item 3).
4.
Tighten support plugs (Figure 3, Item 1).
5.
Remove LO/TO from A3 breaker switch. Refer to FM 4-01.502 for LO/TO procedure.
6.
Start engine (TM 55-1925-205-10).
7.
Start bilge pumps to remove raw water from bilge (TM 55-1925-205-10).
8.
Stop engine (TM 55-1925-205-10).
END OF TASK
END OF WORK PACKAGE