Wrap support plug threads with antiseizing tape.
Figure 2. Butterfly Valve.

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  774    775    776    777    778  779  780    781    782    783    784  
img
. . . . .
TM 55-2815-574-24
0154
FIELD MAINTENANCE
ENGINE 
RAW WATER PUMP ZINC ANODE PLUG REPLACEMENT
INITIAL SETUP:
Tools and Special Tools
References
General mechanic's tool kit
FM 4-01.502
(WP 0179, Table 1, Item 130)
TM 55-1925-205-10
Materials/Parts
Equipment Condition
Antiseizing tape (WP 0178, Table 1, Item 37)
Propulsion module ventilated
Marker tags, with metal eyelet patch Qty: 2
(TM 55-1925-205-23)
(WP 0178, Table 1, Item 36)
Personnel Required
Engineer 88L
REMOVAL
WARNING
Remove all jewelry before conducting maintenance. Do not wear watches, rings,
identification tags, or other jewelry which could short across electrical components or catch
on vehicle components. Failure to comply may result in personnel injury or death.
1.
Place A3 breaker switch (Figure 1, Item 1), located on A10 panel, in OFF position. Refer to
TM 55-1925-205-10 for breaker location.
WARNING
Before attempting any maintenance, ensure power supply (switches, circuit breakers, etc.)
has been disconnected and locked/tagged out against unauthorized accidental start-up or
else death or serious injury due to electric shock and/or moving machinery could occur.
2.
Lock Out/Tag Out (LO/TO) A3 breaker switch (Figure 1, Item 1). Refer to FM 4-01.502 for LO/TO procedure.
Figure 1. A3 Breaker Switch.
0154-1