TM 55-2815-574-24
0155
REMOVAL - Continued
2.
Loosen two clamps (Figure 2, Item 6) at outlet elbow (Figure 2, Item 8) and pump outlet tube
(Figure 2, Item 5).
3.
Slide hose (Figure 2, Item 7) back along pump outlet tube (Figure 2, Item 5).
4.
Drain raw water into bilge.
5.
Loosen two clamps (Figure 2, Item 2) at inlet elbow (Figure 2, Item 4) and pump inlet tube (Figure 2, Item 1).
6.
Slide hose (Figure 2, Item 3) back along pump inlet tube (Figure 2 item 1).
Figure 2. Raw Water Pump and Tubes.
7.
Drain raw water into bilge.
8.
Remove four hex head bolts (Figure 3, Item 2) and lockwashers (Figure 3, Item 1) from pump outlet tube
(Figure 3, Item 8) and remove outlet tube and gasket (Figure 3, Item 7) from raw water pump.
9.
Remove four hex head bolts (Figure 3, Item 3) and lockwashers (Figure 3, Item 4) from inlet tube
(Figure 3, Item 5) and remove inlet tube and gasket (Figure 3, Item 6) from raw water pump.