TM 55-2815-574-24
0037
SERVICING
WARNING
Cleaner may cause irritation to eyes or skin. In case cleaner comes in contact with eyes or
skin, immediately flush eyes with water, wash skin with soap and water. Wear protective
goggles, gloves, and clothing. Failure to comply may result in personnel injury or death.
1.
Clean air box drains with cleaner.
WARNING
Do not exceed 40 PSI (276 kPa) when using compressed air for drying
components. Failure to comply may result in personnel injury or death.
Flying particles and debris are present. Wear protective goggles. Failure to comply
may result in personnel injury or death.
2.
Using air compressor, dry all assemblies thoroughly.
END OF TASK
INSPECTION
NOTE
Repair of air box drain is limited to replacement of hose assembly, check valve, tee fitting,
and pipe fittings.
1.
2.
Inspect all fittings for corrosion and cracking. Replace defective part.
3.
Check all fitting threads for cracking, corrosion, and/or galled threads. Replace defective part.
END OF TASK
0037-3