TROUBLESHOOTING INDEX
Defective engine start pushbutton.

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  31    32    33    34    35  36  37    38    39    40    41  
img
. . .
TM 55-2815-574-24
0005
FIELD MAINTENANCE
ENGINE 
TROUBLESHOOTING PROCEDURES - ENGINE WILL NOT TURN OVER
INITIAL SETUP:
Personnel Required
References (cont.)
Engineer 88L
TM 55-1925-205-23
WP 0032
WP 0038
References
TM 55-1925-205-10
NOTE
The following procedure is typical for both port and starboard engines.
TROUBLESHOOTING PROCEDURE
ENGINE WILL NOT TURN OVER
SYMPTOM
Diesel engine will not turn over.
MALFUNCTION
Loose battery connections.
CORRECTIVE ACTION
1.
Check battery connections and tighten if necessary (TM 55-1925-205-23).
2.
Perform operational check of diesel engine (TM 55-1925-205-10).
MALFUNCTION
Loose starter connections.
CORRECTIVE ACTION
1.
Check connections at starter and tighten if necessary (TM 55-1925-205-23).
2.
Perform operational check of diesel engine (TM 55-1925-205-10).
MALFUNCTION
Low battery voltage.
CORRECTIVE ACTION
Recharge battery if light load test indicates low or no voltage (TM 55-1925-205-23).