Shut engine down (TM 55-1925-205-10).
Remove drain pan and dispose of contents in accordance with local procedures.

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  728    729    730    731    732  733  734    735    736    737    738  
img
. . . . . . . . . .
TM 55-2815-574-24
0142
FIELD MAINTENANCE
ENGINE 
FRESH WATER TEMPERATURE SENDING UNIT REPLACEMENT
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General mechanic's tool kit
Engineer 88L
(WP 0179, Table 1, Item 130)
Air filtering respirator (WP 0179, Table 1, Item 109)
References
Chemical gloves (WP 0179, Table 1, Item 52)
FM 4-01.502
Drain pan (WP 0179, Table 1, Item 87)
TM 55-1925-205-10
Industrial goggles (WP 0179, Table 1, Item 54)
Utility apron (WP 0179, Table 1, Item 8)
Equipment Condition
Propulsion module ventilated
Materials/Parts
(TM 55-1925-205-23)
Hazardous material spill clean-up kit
(WP 0178, Table 1, Item 34)
Marker tags, with metal eyelet patch Qty: 2
(WP 0178, Table 1, Item 36)
REMOVAL
WARNING
Remove all jewelry before conducting maintenance. Do not wear watches, rings,
identification tags, or other jewelry which could short across electrical components or catch
on vehicle components. Failure to comply may result in personnel injury or death.
1.
Place A3 breaker switch (Figure 1, Item 1), located on A10 panel, in OFF position. Refer to
TM 55-1925-205-10 for breaker location.
WARNING
Before attempting any maintenance, ensure power supply (switches, circuit breakers, etc.)
has been disconnected and locked/tagged out against unauthorized accidental start-up or
else death or serious injury due to electric shock and/or moving machinery could occur.
2.
Lock Out/Tag Out (LO/TO) A3 breaker switch (Figure 1, Item 1). Refer to FM 4-01.502 for LO/TO procedure.
Figure 1. A3 Breaker Switch.