Remove drain pan and dispose of contents in accordance with local procedures.
FRESH WATER COOLING SYSTEM BYPASS HOSES REPLACEMENT

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  730    731    732    733    734  735  736    737    738    739    740  
img
.
TM 55-2815-574-24
0142
INSTALLATION - Continued
Figure 2. Thermostat Housing.
5.
Remove LO/TO from A3 breaker switch. Refer to FM 4-01.502 for LO/TO procedure.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Service fresh water cooling system (TM 55-1925-205-10).
2.
Clean up spilled fluid with spill clean-up kit and dispose of spill clean-up kit waste in accordance with local
procedures.
END OF TASK
END OF WORK PACKAGE
0142-3/blank