TM 55-2815-574-24
0173
REMOVAL - Continued
3.
Verify fuel supply and return valves (Figure 2, Item 1) are closed.
Figure 2. Fuel Supply and Return Valves.
4.
Position drain pan under fuel oil pressure switch (Figure 3, Item 2).
5.
Tag and disconnect wiring (Figure 3, Item 1) from fuel oil pressure switch (Figure 3, Item 2).
WARNING
Fuel is flammable and should not be exposed to open flame. Always keep fire
extinguisher within easy reach when working with fuel.
Fuel is toxic and may cause irritation to the eyes, lungs, or skin. Always wear eye
and hand protection, and ensure that you are in a well-ventilated area when
handling fuel.
Fuel is slippery and may cause falls. Mop up spills immediately.
Fuel is an environmental hazard. Accidental or intentional introduction of liquid
contaminants into the environment may result in a violation of state, federal, and
military regulations. Refer to local environmental office for information concerning
storage, use, and disposal of these liquids.
Failure to comply may result in personnel injury, death, and/or damage to equipment and
environment.
6.
Remove fuel oil pressure switch (Figure 3, Item 2) from mount fitting (Figure 3, Item 3) by turning
counterclockwise.
7.
Remove drain pan and dispose of contents in accordance with in accordance with local procedures.
END OF TASK