ELECTRONIC GOVERNOR ACTUATOR STAYS AT MINIMUM POSITION WHEN POWER IS APPLIED -
Continued
MALFUNCTION
Incorrect voltage between terminal 7 and terminal 2.
CORRECTIVE ACTION
1.
With DC power to the governor on and engine off, measure DC voltage from terminal 7 (+) to
terminal 2 (-). It should be approximately 4 VDC. If 4 VDC is not present,
2.
Perform operational check of the electronic governor actuator (TM 55-1925-205-10).
END OF WORK PACKAGE