ELECTRONIC GOVERNOR ACTUATOR STAYS AT MINIMUM POSITION WHEN POWER IS APPLIED - Continued
TROUBLESHOOTING PROCEDURES - ELECTRONIC GOVERNOR GOES TO FULL STROKE WHEN DC POWER IS APPLIED AND ENGINE IS NOT OPERATING

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  76    77    78    79    80  81  82    83    84    85    86  
img
.
TM 55-2815-574-24
0021
ELECTRONIC GOVERNOR ACTUATOR STAYS AT MINIMUM POSITION WHEN POWER IS APPLIED -
Continued
MALFUNCTION
Incorrect voltage between terminal 7 and terminal 2.
CORRECTIVE ACTION
1.
With DC power to the governor on and engine off, measure DC voltage from terminal 7 (+) to
terminal 2 (-). It should be approximately 4 VDC. If 4 VDC is not present,
replace controller (WP 0099).
2.
Perform operational check of the electronic governor actuator (TM 55-1925-205-10).
END OF WORK PACKAGE
0021-4