TROUBLESHOOTING PROCEDURES - ELECTRICAL GENERATING SYSTEM SHOWS FULLY CHARGED BATTERY AND HIGH CHARGING RATE
Binding electronic governor drive.

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  73    74    75    76    77  78  79    80    81    82    83  
img
. . . . . . . .
TM 55-2815-574-24
0021
FIELD MAINTENANCE
ENGINE
TROUBLESHOOTING PROCEDURES - ELECTRONIC GOVERNOR ACTUATOR STAYS AT MINIMUM
POSITION WHEN POWER IS APPLIED
INITIAL SETUP:
Tools and Special Tools
References (cont.)
General mechanic's tool kit
WP 0097
(WP 0179, Table 1, Item 97)
WP 0098
Multimeter
WP 0099
(WP 0179, Table 1, Item 59)
WP 0100
Personnel Required
Engineer 88L
References
TM 55-1925-205-10
NOTE
This troubleshooting procedure is typical for both port and starboard engines.
TROUBLESHOOTING PROCEDURE
ELECTRONIC GOVERNOR ACTUATOR STAYS AT MINIMUM POSITION WHEN POWER IS APPLIED
SYMPTOM
Electronic governor, engine junction box A4, is completely dead, actuator lever stays at minimum position
when power is applied to governor.
MALFUNCTION
No battery voltage at terminals 1 and 2 on controller.
CORRECTIVE ACTION
1.
Use a multimeter to check electrical connections and contacts for power at controller.
2.
Perform operational check of electronic governor actuator (TM 55-1925-205-10).
MALFUNCTION
Binding or defective linkage.
CORRECTIVE ACTION
1.
Inspect governor rod assembly (WP 0097).
2.
Perform operational check of electronic governor actuator (TM 55-1925-205-10).