• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
ELECTRONIC GOVERNOR ACTUATOR STAYS AT MINIMUM POSITION WHEN POWER IS APPLIED - Continued
ELECTRONIC GOVERNOR GOES TO FULL STROKE WHEN DC POWER IS APPLIED AND ENGINE IS NOT OPERATING - Continued

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  77    78    79    80    81  82  83    84    85    86    87  
img
. . . . . .
TM 55-2815-574-24
0022
FIELD MAINTENANCE
ENGINE
TROUBLESHOOTING PROCEDURES - ELECTRONIC GOVERNOR GOES TO FULL STROKE WHEN DC
POWER IS APPLIED AND ENGINE IS NOT OPERATING
INITIAL SETUP:
Tools and Special Tools
References (cont.)
General mechanic's tool kit
TM 55-1925-205-23
(WP 0179, Table 1, Item 97)
WP 0099
Multimeter
WP 0100
(WP 0179, Table 1, Item 59)
Personnel Required
Engineer 88L
References
TM 55-1925-205-10
NOTE
This following procedure is typical for both port and starboard engines.
TROUBLESHOOTING PROCEDURE
ELECTRONIC GOVERNOR GOES TO FULL STROKE WHEN DC POWER IS APPLIED
AND ENGINE IS NOT OPERATING
SYMPTOM
Electronic governor actuator goes to full stroke when Direct Current (DC) power is applied and engine
is not operating.
MALFUNCTION
Magnetic pick-up leads not shielded.
CORRECTIVE ACTION
1.
Verify magnetic pick-up leads are shielded. If they are not, correct wiring as necessary
(TM 55-1925-205-23).
2.
Perform operational check of the electronic governor actuator (TM 55-1925-205-10).
MALFUNCTION
Damaged magnetic pick-up coil.
CORRECTIVE ACTION
Replace electronic governor magnetic pick-up (WP 0100).
0022-1