Figure 13. Mounting Hardware Installation.
Perform operational checks (TM 55-1925-205-10).

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  669    670    671    672    673  674  675    676    677    678    679  
img
. . .
TM 55-2815-574-24
0128
INSTALLATION - Continued
Figure 15. Oil Cooler Housing Installation.
WARNING
Accidental or intentional introduction of liquid contaminants into the environment
may result in a violation of state, federal, and military regulations. Refer to local
environmental office for information concerning storage, use, and disposal of
these liquids. Failure to comply may cause damage to environment and health
of personnel. Seek medical attention in the event of injury.
Fuel/solvent/oil is slippery and may cause falls. Wipe up spillage immediately with
rags. Dispose of materials in accordance with local hazardous waste disposal
procedures. Failure to comply may result in personnel injury or death and/or
damage to equipment.
30.
Clean up spilled fluid with a spill kit and dispose of spill kit waste in accordance with local procedures.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install overspeed governor. Contact Maintenance Supervisor.
2.
Install marine gear oil cooler mounting bracket (WP 0158).
3.
Install marine gear oil cooler (TM 55-1925-319-23).
4.
Service lube oil system (WP 0115).
5.
Service engine fresh water cooling system (TM 55-1925-205-10).