• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Check the clearance between each rotor lobe
Table 1. Chart of Minimum Blower Clearances - Continued.

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  588    589    590    591    592  593  594    595    596    597    598  
img
TM 55-2815-574-24
0111
ASSEMBLE - Continued
Table 1. Chart of Minimum Blower Clearances.
CLEARANCES
BLOWER PART NO.
ENGINE
A
B
C
CC
D
E
5101483
8V-TA
0.007
0.019
0.010
0.006
0.015
0.005
5101484
8V-TAE
0.007
0.019
0.010
0.006
0.015
0.005
5104937
8V
0.007
0.019
0.010
0.006
0.015
0.005
5144787
8V
0.007
0.014
0.010
0.006
0.015
0.005
5144893
8V
0.007
0.014
0.010
0.006
0.015
0.005
5146912
8V
0.007
0.012
0.010
0.006
0.015
0.005
5147152
8V
0.012
0.019
0.010
0.006
0.030
0.005
8920613
8V-TAE
0.007
0.019
0.010
0.006
0.015
0.005
8921938
8V-TA
0.007
0.019
0.010
0.006
0.015
0.009
8923371
8V-TAE
0.007
0.019
0.010
0.006
0.015
0.005
8923474
8V-TA
0.007
0.019
0.010
0.006
0.015
0.007
8923475
8V-TA
0.007
0.019
0.010
0.006
0.015
0.007
8923476
8V-TA
0.007
0.019
0.010
0.006
0.015
0.007
8926407
8V-TA
0.007
0.012
0.010
0.006
0.015
0.005
8926408
8V-TA
0.007
0.019
0.010
0.006
0.015
0.005
8926616
8V-TA
0.007
0.019
0.010
0.006
0.015
0.005
8927037
8V-TA
0.007
0.019
0.010
0.006
0.015
0.007
8927041
8V-TA
0.007
0.019
0.013
0.013
0.015
0.009
8927043
8V-TA
0.007
0.019
0.010
0.006
0.015
0.007
8927468
8V-TA
0.007
0.019
0.010
0.006
0.015
0.009
23501076
8V-TA
0.007
0.012
0.010
0.010
0.015
0.007
23501261
8V-TA
0.007
0.019
0.010
0.006
0.015
0.009
23501842
8V-TA
0.007
0.019
0.010
0.010
0.015
0.009
0111-22