Install SINCGARS antenna (TM 11-5820-890-10-8).
Tag and disconnect wires from switch

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  836    837    838    839    840  841  842    843    844    845    846  
img
. . . . . . . .
TM 55-2815-574-24
0171
FIELD MAINTENANCE
ENGINE 
AUTO SHUTDOWN SYSTEM HIGH WATER TEMPERATURE SWITCH REPLACEMENT
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General mechanic's tool kit
Engineer 88L
(WP 0179, Table 1, Item 130)
Drain pan (WP 0179, Table 1, Item 87)
References
Utility apron (WP 0179, Table 1, Item 8)
FM 4-01.502
TM 55-1925-205-10
Materials/Parts
Antiseizing tape (WP 0178, Table 1, Item 37)
Equipment Condition
Hazardous material spill clean-up kit
Propulsion module ventilated
(WP 0178, Table 1, Item 34)
(TM 55-1925-205-23)
Marker tags, with metal eyelet patch Qty: 2
(WP 0178, Table 1, Item 36)
REMOVAL
WARNING
Remove all jewelry before conducting maintenance. Do not wear watches, rings,
identification tags, or other jewelry which could short across electrical components or catch
on vehicle components. Failure to comply may result in personnel injury or death.
1.
Place A3 breaker switch (Figure 1, Item 1), located on A10 panel, in OFF position. Refer to
TM 55 1925-205-10 for breaker location.
WARNING
Before attempting any maintenance, ensure power supply (switches, circuit breakers, etc.)
has been disconnected and locked/tagged out against unauthorized accidental start-up or
else death or serious injury due to electric shock and/or moving machinery could occur.
2.
Lock Out/Tag Out (LO/TO) A3 breaker switch (Figure 1, Item 1). Refer to FM 4-01.502 for LO/TO procedure.
Figure 1. A3 Breaker Switch.
0171-1