TM 55-2815-574-24
0102
CLEANING
WARNING
Cleaner may cause irritation to eyes or skin. In case cleaner comes in contact with eyes or
skin, immediately flush eyes with water, wash skin with soap and water. Wear protective
goggles, gloves, and clothing. Failure to comply may result in personnel injury or death.
1.
Clean all parts with cleaner.
WARNING
Do not exceed 40 PSI (276 kPa) when using compressed air for checking
components. Failure to comply may result in personnel injury or death.
Flying particles and debris are present. Wear protective goggles. Failure to comply
may result in personnel injury or death.
2.
Dry all parts with compressed air.
END OF TASK
INSPECTION
1.
Inspect remote control lever (Figure 1, Item 12) for cracks or warping. Replace damaged remote
control lever.
2.
Inspect the shaft and lever assembly (Figure 1, Item 2) for cracks, corrosion, pitting or warping. Replace
damaged shaft and lever assembly.
3.
Inspect housing (Figure 1, Item 5) for cracks or any damage that will prevent sealing. Replace
damaged housing.
4.
Inspect tubes (Figure 1, Item 1) for cracks or dents. Replace damaged tubes.
END OF TASK
0102-3