• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Install woodruff key into shaft of shaft and lever assembly.
Figure 1. A3 Breaker Switch.

TECHNICAL MANUAL FIELD AND SUSTAINMENT MAINTENANCE MANUAL FOR ENGINE 8V92TA
Page Navigation
  534    535    536    537    538  539  540    541    542    543    544  
img
. . . . . . . . . . . . . .
TM 55-2815-574-24
0103
FIELD MAINTENANCE
ENGINE 
AIR INTAKE HOUSING REPAIR
INITIAL SETUP:
Tools and Special Tools
References
General mechanic's tool kit
FM 4-01.502
(WP 0179, Table 1, Item 130)
TM 55-1925-205-10
Chemical gloves (WP 0179, Table 1, Item 52)
Industrial goggles (WP 0179, Table 1, Item 54)
Equipment Condition
Reciprocating compressor unit power drive
Propulsion module ventilated
(WP 0179, Table 1, Item 27)
(TM 55-1925-205-23)
Stencil brush (soft bristle)
Engine cool to touch
(WP 0179, Table 1, Item 20)
Single channel ground and airborne radio system
Utility apron (WP 0179, Table 1, Item 8)
(SINCGARS) antenna removed
(TM 11-5820-890-10-8) Main
navigation mast removed (TM
Materials/Parts
55-1925-205-10)
Ball and roller bearing grease
Operator's cab removed (TM 55-1925-205-10)
(WP 0178, Table 1, Item 22)
Intake plenum removed (TM 55-1925-205-10)
Cleaner (WP 0178, Table 1, Item 8)
Powered section engine hatch removed
Gasket Qty: 2 (WP 0180, Table 1, Item 66)
(TM 55-1925-205-10)
Lockwasher Qty: 6 (WP 0180, Table 1, Item 106)
Emergency stop solenoid removed (WP 0170)
Marker tags, with metal eyelet patch Qty: 2
(WP 0178, Table 1, Item 36)
Ring seal Qty: 2 (WP 0180, Table 1, Item 60)
Personnel Required
Engineer 88L
REMOVAL
WARNING
Remove all jewelry before conducting maintenance. Do not wear watches, rings,
identification tags, or other jewelry which could short across electrical components or catch
on vehicle components. Failure to comply may result in personnel injury or death.
1.
Place A3 breaker switch (Figure 1, Item 1), located on A10 panel, in OFF position. Refer to
TM 55-1925-205-10 for breaker location.
WARNING
Before attempting any maintenance, ensure power supply (switches, circuit breakers, etc.)
has been disconnected and locked/tagged out against unauthorized accidental start-up or
else death or serious injury due to electric shock and/or moving machinery could occur.
2.
Lock Out/Tag Out (LO/TO) A3 breaker switch (Figure 1, Item 1). Refer to FM 4-01.502 for LO/TO procedure.
0103-1


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.