TM 55-2815-574-24
0052
TESTING - Continued
WARNING
Do not exceed 40 PSI (276 kPa) when using compressed air for checking
components. Failure to comply may result in personnel injury or death.
Flying particles and debris are present. Wear protective goggles. Failure to comply
may result in personnel injury or death.
17.
Apply 40 PSI (275.79 kPa) to cylinder head (Figure 7, Item 7).
18.
Check for leakage around water inlet ports (Figure 7, Item 6).
Figure 7. Test Fixture Installation.